Infant Baby, Pediatric Care Hospital Machines, Equipments And Solutions

HomeProductsInfant (Baby / Pediatric) Care Hospital Machines / Equipments And Solutions


We are Manufacturer, Supplier, Exporter of Infant Baby, Pediatric Care Hospital Machines Equipments, Infant Radiant Warmer with Fixed Baby Cradle Skin, Air and Manual, Radiant Warmer for Newborn, Neonatal Resuscitation Units, Warmer With LED Phototherapy, LED Photo Therapy with Trolley, Led Phototherapy Units from Ichalkaranji, Kolhapur, Maharashtra, India.
We provide our whole range to ALL OVER THE WORLD.

Infant Baby, Pediatric Care Hospital Machines, Equipments Manufacturer

MS 1803F:- Infant Radiant Warmer with Fixed Cradle (Skin, Air & Manual)

Micro Controller based PID Servo Temperature Controller Baby Cradle with mattress, variable head up/down facility, x ray cassette holder Drop Down side supports, Two lower shelfs for under surface phototherapy and storage Swivelling Source hood consists of heating element and LED examination light Side Mounted Monitor tray, Pole for Syringe Pump / Infusion Pump & S.S. IV Stand


Specifications :

  • Two Lower Shelfs
  • Ceramic Heater, 650 W
  • Led Examination Lamp
  • Transparent 6mm Drop Down Side Supports
  • Tilting Of Baby Tray
  • Castors With Lock

Features :

  • 1”bright skin temp.Display
  • 1”bright air temp.Display
  • % of heater output display on Bar Graph
  • Separate Set temp. display
  • Temperature display in C or F
  • Count Up Timer (APGAR)
  • Count Down Timer (Feed)
  • Baby attending alarm
  • Mutetime programmable
  • Audio Alarm mute facility
  • Resolution of 0.1
  • TempAccuracyof+/-0.3

Skin Mode :

  • Skin Temp. High (>1.5°C of set temp.)
  • Skin Temp. Low (<1.5°C of set temp.)
  • Skin Temp. Over Range (>38°C)
  • Skin Temp. Under Range (<34°C)
  • Skin Probe Fail

Safety High Temp. Cutoff At :

  • Skin Temp.> 38°C
  • Air Temp.> 39°C
  • ower Fail Heater Fail System Fail

Manual Mode :

  • Time programmable
  • Heater output adjustable
  • Over temp. Cutoff
  • Air Temp. High (>1.5°C of set temp.)
  • Air Temp. Low (<3.0°C of set temp.)
  • Air Temp. Over Range (>39°C)
  • Air Probe Fail

MS 174DT - Neonatal Resuscitation Unit

Micro Controller based PID Servo Temperature Controller Baby Cradle with mattress, variable head up/down facility, Drawers Drop Down side supports, Two lower shelfs, x-ray cassette holder


Features :

  • 1” bright Skin & Air temp. display
  • % of heater output display on Bar Graph
  • Temperature display in C or F
  • Set temp. display on LCD
  • Control mode display on LCD
  • APGAR Timer display on LCD Feed
  • Timer
  • Baby attending alarm
  • Mute time programmable
  • Audio Alarm mute facility
  • Side Mounted Monitor tray
  • Pole for Syringe/Infusion Pump
  • S.S. IV Stand
  • LED examination light
  • HI and LO Alarms for Skin and Air
  • Skin Temp.> 38°C
  • Air Temp.> 39°C
  • Power Fail
  • Heater Fail
  • System Fail

Attachments :

  • Oxygenation
  • Oxygen regulator
  • Flow meter
  • Humidifier bottle
  • Manual Silicone Resuscitation Bag with 2 masks
  • Oxygen tubing
  • Place to keep cylinder
  • Oxygen hood
  • Inline Manometer
  • To monitor pressure delivered by Resuscitation Bag
  • Suction
  • Electric Suction with One Bottles and Regulator
  • Intubation
  • Laryngoscope with 0 & 1 straight blades, ET tubes, Silicone Airways